About Power Cables
Mains leads and extensions for stage and event work, built predominantly by Elumen8 and LEDJ on H07RN-F rubber flex. The range covers powerCON TRUE1 TOP extensions, 13A to TRUE1 fixture leads, Schuko to TRUE1 adaptor cables, PowerTwist TR1 IP65 assemblies, IEC leads and TRUE1-fed 13A four-gang breakouts, with Mennekes-ended options alongside.
Start from the two ends. The lead has to match the fixture inlet on one side and whatever the distro actually offers on the other, which is why 13A to TRUE1 and Schuko to TRUE1 conversions dominate real-world rigs: the fixture manufacturer and the venue rarely agree. Check the inlet on your own fixtures before ordering a batch, because powerCON TRUE1 and the original powerCON are deliberately not intermateable, and a box of the wrong ones is an expensive afternoon.
Jacket and conductor size are the next two decisions. H07RN-F rubber flex is the right specification for stage and site use: it shrugs off abrasion, stays flexible in the cold and survives being dragged and coiled wet, where PVC hardens and cracks. Conductor size should be matched to the load and the run length, with 1.5mm² covering typical fixture-level loads across the lengths stocked here and 2.5mm² where the current or the distance rises. For outdoor and damp positions, pick the IP-rated TRUE1 TOP and TR1 IP65 assemblies rather than taping over a standard connector.
Breakouts deserve a second look before they are daisy-chained. A four-gang on the end of a single drop concentrates four loads onto one circuit, and it is easy to end up with far more connected than the feed allows once other people start plugging in. Add the draw up first, and label the drop with what it is feeding.
Bare connectors for building your own assemblies are in the Connectors section, bulk cable by the hundred metres is in Cable Drums, and distribution to feed all of it sits under Power Distribution.
The event power guide covers the supply side from 13A to Powerlock, stage power for bands is the practical checklist for small events, and cable care covers coiling, testing and why a fully wound drum under load is a fire risk.
Power Cable FAQs
Why do 13A-to-TRUE1 leads dominate real rigs? Because fixture manufacturers ship TRUE1 inlets and venues offer 13A sockets, the conversion lead bridges the two. Match the fixture inlet on one end and what the distro actually offers on the other.
What is H07RN-F and why does it matter? Harmonised rubber flex rated for rough service, the jacket that survives stages, weather and nightly coiling. It is the baseline spec for every lead here.
How long is too long? Length costs voltage drop, and the symptom is misbehaving kit at the far end. Size conductor cross-section to load and run, the maths is in power distribution explained.